DC/AC current measurable max. 2000A, CAT.IV 1000V
・Dual display shows voltage/current and its frequency
・EF (Electric Field) detection
・VFD (Variable Frequency Drive) frequency measurement
・Low input impedance voltage measurement capable of attenuating the effects of ghost voltages
・Peak hold (Interval: 5 ms)
・Auto power save (30 min./Cancelable)
Report Abuse
Features
Max 2000A
True RMS (True root-mean-square value)
True RMS value. AC current and voltage of a non-sine wave can be measured by true RMS values.
DC / AC measurable
Both ACA and DCA are measurable.
Frequency
Expressed in the unit of Hz (hertz). Commercial frequency of 50Hz/60Hz can be measured.
Continuity buzzer
The buzzer sounds when the measuring object is electrically conducting.
EF function
Non-contact AC voltage detection
peak hold
The peak value like in-rush current is indicated. The minimum pulse width capturable differs according to models.
Low-pass filter
Low-pass filter cuts current value of high frequency.
Automatic Measurement for DCV/ACV/Ω
Measurement function of DCV/ACV/Ωcan be automatically selected.
Auto power save
The display disappears to bring the device into the power-save state when a certain time has passed after power-up. Some models have a function to cancel this function.
Data hold
A value indicated on the display is fixed. It is fixed even after the test lead is removed, and can be used as a record for reference purposes.
Range hold
The range is fixed in the measurement of varying voltage and current which is difficult to read in the auto range.
Measurement of relative value
A certain measured value is assumed as 0 and measured values after that are expressed by positive or negative values relative the value fixed as 0.
Backlight
Allows indicator reading in a dark place.
Specifications
Function | Measuring range | Best accuracy | Resolution |
---|---|---|---|
ACA | 200.0/2000A | ±(2.0%+5) | 0.1A |
DCA | 200.0/2000A | ±(2.0%+5) | 0.1A |
ACV | 6.000/60.00/600.0/1000V | ±(1.2%+5) | 0.001V |
DCV | 6.000/60.00/600.0/1000V | ±(0.5%+5) | 0.001V |
Resistance | 600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ | ±(0.5%+5) | 0.1Ω |
Frequency | 10~1999Hz | ±(0.1%+4) | 0.01Hz |
Capacitance | 60n/600n/6μ/60μ/600μ/2000μF | ±(2.0%+5) | 0.01nF |
Continuity | Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V | ||
Diode test | Open voltage: approx. 1.8V | ||
EF sensing | A voltage or electric field of about 60 V or more is detected. The bar graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz) |
Sampling rate | Approx. 5 times/sec. | ||
Bandwidth | 50~400Hz | ||
Display | 6000/1999(Hz) | ||
Max. overload protection input | DC/AC1100V CT: DC/AC2000A | ||
Clamp diameter/Conductor size | Φ55mm/20x66mm | ||
Battery | R6Px2 | ||
Battery life | A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off) | ||
Size/Mass | H264×W97×D43mm/Approx. 640g | ||
Safety standards | IEC61010 CAT.Ⅳ1000V |
Measurements only become meaningful when there is confidence in the accuracy and the quality of the instruments being used.
Sanwa’s mission is to deliver unique measuring instruments to its customers. Placing customer trust and satisfaction first and foremost, Sanwa works to contribute to global environmental conservation and energy management through the continuous evolution of electrical and on-site measuring instruments.
Need more info ?
CLAMP METER DCM2000DR Catalog
Sanwa Electric Instrument Co., Ltd.
Supplier Information
- Store Name: Sanwa Electric Instrument Co., Ltd.
- Vendor: Sanwa Electric Instrument Co., Ltd.
- Address: 101-0021
Tokyo Chiyoda-ku 4-4 Sotokanda 2-Chome
- Physical Measuring Instruments, Speed Measuring Instruments, Testing Instrument & Equipment
SPEED METER SE9100 – Sanwa Electric Instrument Co. Ltd.
Physical Measuring Instruments, Speed Measuring Instruments, Testing Instrument & EquipmentSPEED METER SE9100 – Sanwa Electric Instrument Co. Ltd.
Speedometer for elevator/lift and measurement of escalator emergency stop distance
・Speed of high speed elevator can be measured up to 2000.0 m/min
・Two independent data hold (CH1/CH2) functions plus maximum value hold function
・Memory storage of held value and maximum value
・Data hold by external triggering
・Movement average value display (average frequency setting can be set at any of 1 to 10 times)
・Analog output of measurement value
・Measurement of emergency stop distance for a escalatorSKU: n/a - Testing Equipment, Testing Instrument & Equipment
DIGITAL EARTH TESTER PDR4000 – Sanwa Electric Instrument Co. Ltd.
Testing Equipment, Testing Instrument & EquipmentDIGITAL EARTH TESTER PDR4000 – Sanwa Electric Instrument Co. Ltd.
Easy to read with backlight
・Three measurement ranges: 40Ω, 400Ω, 4000Ω
・3-pole/2-pole earth resistance measurement
(Optional accessory TL-68 is necessary for 2-pole measurement.)
・Auto power off (10 min./Cancelable)
・Capable of measuring interference voltage
・2mA measuring currentSKU: n/a