HICLAVE HVP series – HIRAYAMA Manufacturing Corporation
This autoclave is made by incorporating a high performance vacuum pump into the HV series autoclave and equipped with fully automatic drying function.
Clean drying without contamination
Pre-vacuum air removal using a vacuum pump
Electro-mechanical lid lock system
Dual interlock mechanism
Report Abuse
Features & Functions
Clean drying without contamination
After sterilization, drying is performed with the lid closed.
Clean drying can be carried out without worry of contamination.
Pre-vacuum air removal using a vacuum pump
A vacuum pump is installed to remove residual air with vacuum.
This is effective when sterilizing objects put in containers or bags from which air is difficult to escape.
Electro-mechanical lid lock system
The lid can be opened and closed easily and reliably with the one-touch lever.
A pressure seal method is used as a safety measure.
Dual interlock mechanism
The lid is locked by dually detecting the chamber pressure and chamber temperature during operation.
The lock state is maintained even if an operation is manually interrupted.
Memory function
Set contents can be registered for each mode.
Options for upgrading a system
Recorder |
---|
(Image is a chart type recorder.) ・Chart type recorder: 6-point dotting ・Hybrid recorder: 8-point dotting ※Chart width: 100 mm ※Class 2 T-type thermocouple included |
Display panel
Operation cycle of each mode
Option
Stainless steel round wire basket | Sterilization bucket, stainless steel | Round dressing drum stainless steel |
---|---|---|
φ270 x H220 mm φ270 x H270 mm | φ270 x H220 mm φ270 x H270 mm | [Small] φ170 x H120 mm[Medium] φ200 x H150 mm[Large] φ260 x H180 mm |
Sterilization tape, Sterilization label, Sterilization bag |
---|
■Sterilization tape: Clear color change makes it easy to identify exposure to sterilization process. ■Sterilization label: Paste directly on the object to be sterilized, you can check the sterilization treatment. After sterilization, the letters “sterilized” appear and it can be easily distinguished from untreated materials. ■Sterilization bag: There are sterilization bags that are made of paper, roll type or one seal back type. Most of them are heat seal type, but tape seal type and aluminum plate seal type can be also available.※Ask us for prices and more details. |
“STERILIZING SIMPLY AND WELL”
Since its foundation in 1924, we have continued to pursue the fields of medical and scientific equipment for 90 years, with various sterilizations, incubators, and highly accelerated stress test chambers as our main products.
Need more info ?
HVP-50 Vertical Autoclave with Drying Cycle
HIRAYAMA Manufacturing Corporation
Supplier Information
- Store Name: HIRAYAMA Manufacturing Corporation
- Vendor: HIRAYAMA Manufacturing Corporation
- Address: 345-0845
Saitama Kasukabe-shi 2-6-5 Toyono-cho
- Hast Chamber, Testing Equipment, Testing Instrument & Equipment
Highly Accelerated Stress Test Chamber PC-702R8 – HIRAYAMA Manufacturing Corporation
Hast Chamber, Testing Equipment, Testing Instrument & EquipmentHighly Accelerated Stress Test Chamber PC-702R8 – HIRAYAMA Manufacturing Corporation
A dual vessel structured HAST chamber with color touch panel has many superiorities.
There are two types of operation modes.
A fixed-value operation mode, and a programmed operation mode that allows registration of total 1500 steps within maximum 150 operation patterns are equipped.SKU: n/a - Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer
High Pressure Steam Sterilizer HVE-50 – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHigh Pressure Steam Sterilizer HVE-50 – HIRAYAMA Manufacturing Corporation
Easy operation. More safety and more user-friendly features !
User-Friendly Features and Improved Basic Performance User-Friendly Features and Improved Basic Performance
1. Electromechanical lock system.
2. Dual-sensing interlock mechanism.
3. Pulse exhaust system (HVE-50).
4. Memory function (program your own).
1. Electromechanical lock system.
2. Dual-sensing interlock mechanism.
3. Pulse exhaust system (HVE-50).
4. Memory function (program your own).
5. Space – saving design.
6. Process status display.
7. Forced cooling fan as
standard equipment (HVA-85/110)
and provided as option (HVE-50).SKU: n/a - Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer
Full-automatic Autoclave with Drying Function HRH – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerFull-automatic Autoclave with Drying Function HRH – HIRAYAMA Manufacturing Corporation
Horizontal Autoclave with One-touch Lid Interlock System
Clean drying without contamination
Pre-vacuum air removal using a vacuum pump
Electro-mechanical lid lock system
Dual interlock mechanism
Dual detection system for residual airSKU: n/a - Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer
HICLAVE HV-Ⅱ series – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHICLAVE HV-Ⅱ series – HIRAYAMA Manufacturing Corporation
Sterilization as expected. Color touch panel
Color touch panel
Electro-mechanical lid lock system
Memory function
Dual interlock mechanism
Lid lock release temperature setting
Air removal time setting
Forced cooling unit(option)SKU: n/a - Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer
HICLAVE HVA series – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHICLAVE HVA series – HIRAYAMA Manufacturing Corporation
Large capacity, Economical and excellent cost performance.Forced cooling unit as standard
Electro-mechanical lid lock system
Dual interlock mechanism
Forced cooling unitSKU: n/a - Testing Equipment, Testing Instrument & Equipment
Saturated Pressure Cooker Test Chamber (PCT chamber) PC-242HS series – HIRAYAMA Manufacturing Corporation
Testing Equipment, Testing Instrument & EquipmentSaturated Pressure Cooker Test Chamber (PCT chamber) PC-242HS series – HIRAYAMA Manufacturing Corporation
PCT chamber downsized to almost same size as household microwave oven.
Wide test condition setting range
The PC-242HS series PCT chambers can be used in a wide range of fields, such as: moisture resistance evaluation of new materials, performance comparison test at development, storage test of electronic parts, identification of defective lots, surface treatment evaluation tests for lead pins, materials and plated parts, accelerated deterioration test for various paint-related materials. Test conditions of 100℃ and 100% RH are also available.SKU: n/a