Water-cooled cooling system (standard and inverter) – Hitachi Global Life Solutions Inc.
Inverter compressor improves water temperature accuracy.
Improved performance during low-load operation realizes high energy-saving performance.
In addition, a module control function is standard.
Product Features
Inverter Compressor Improves Water Temperature Accuracy
The operating capacity of the compressor is controlled by an inverter according to the load to improve the water temperature accuracy of the cold water outlet water temperature and supply it to the load.
Significant reduction in annual power consumption*1 due to improved performance during low-load operation
In the case of 50Hz district/industrial cooling
Trial calculation conditions
Operating month: January to December – Operating hours: 8:00 to 19:00 – Operating days: 240 days/year – Outside air: (Tokyo) Japan Meteorological Agency data – Standard load:
Model 90 6.4kW (rated capacity 8.0kW x 0.8)
Model 150: 10.56 kW (rated capacity 13.2 kW x 0.8)
Model 224 16.0kW (Rated capacity 20.0kW x 0.8)
Model 300 21.2kW (Rated capacity 26.5kW x 0.8)
Model 450 32.0kW (Rated capacity 40.0kW x 0.8)
Model 600 42.4kW (Rated capacity 53.0kW x 0.8)
In case of 60Hz district/industrial cooling
Trial calculation conditions
Operating month: January to December – Operating hours: 8:00 to 19:00 – Operating days: 240 days/year – Outside air: (Osaka) Japan Meteorological Agency data – Standard load:
Model 90 7.2kW (rated capacity 9.0kW x 0.8)
Model 150: 12 kW (rated capacity 15.0 kW x 0.8)
Model 224 17.92kW (Rated capacity 22.4kW x 0.8)
Model 300 24kW (Rated capacity 30.0kW x 0.8)
Model 450 36kW (Rated capacity 45.0kW x 0.8)
Model 600 48kW (Rated capacity 60.0kW x 0.8)
*Conventional fixed speed machines: Products on the market until March 2018.
Equipped with module control function as standard to accommodate a variety of local systems
Controls up to 8 modules per group (maximum cooling capacity 480 kW)
Module control function is equipped as standard. No dedicated controller for controlling the number of modules is required. (The “system operation button” of the optional component of the “hand-held system operation kit” or input of operation commands from a remote location is required.
*Use the same combination of capacities for controlling the number of units. In the factory default setting of this model, the “number control cancel function” is enabled. If you want to use the “number control” function, set the “number control cancel function” to “OFF” and disable it.
Main module control functions
Number control function
The number of modules is controlled according to the load. (It is also possible to turn on/off all modules simultaneously without controlling the number of modules.
Rotation function
The operation time of each module is monitored, and each module is rotated so that the operation time is equalized. Priority can also be assigned to each module.
Operation in case of abnormal shutdown
The risk of complete shutdown can be avoided. When the first module (parent unit) stops abnormally, the first module itself is disconnected and operation is continued in the same way.
Setting the number of startup modules and limiting the number of modules in operation
The number of units to be started up at system startup can be set regardless of the load status. The minimum and maximum number of units during operation can also be limited, allowing selection of an operation method that matches the load and power conditions.
Hand-held system operation kit (optional component)
System operation/shutdown can be performed at the user’s hand.
This kit consists of a system operation/stop button and wiring for hand-held operation. Please install locally using the knockout holes.
*Door is open.
Preparation of built-in active filter (AF) for harmonics countermeasures (for modification) (except models 90 and 150)
A built-in active filter (AF) that can be installed inside the chiller unit is available as a harmonic countermeasure. (Shipped with the main unit built in.) ● 6-pulse conversion coefficient (Ki)
List of 6 pulse conversion coefficients (Ki value)
Active filter (AF) mounting position
Easy installation and installation by elevator
Can be carried in by an elevator*1
The unit can be carried in by an 11-seat elevator.
External dimensions
(mm) Model
Model Height Width Depth
90-inch and 150-inch models 1,380 820 500
224/300 Type 1,380 950 500
Type 450 and 600 1,380 1,210 640
Elevator dimensions
(mm)
Door opening
Height Depth Door opening
Width
Elevator
(11-seater) 2,100 1,350 800
1 Elevator (11-seater): JIS A 4301-1983
Expanded capacity control range
The lower limit of the capacity control range has been expanded by installing an inverter compressor. Even at low loads, chilled water can be supplied at a more stable outlet water temperature.
Lower limit of capacity control range for standard specifications
Model name
(Cooling capacity kW) Model 90
(9.0) Model 150
(15.0) Model 224
(22.4) Model 300
(30.0) Model 450
(45.0) Model 600
(60.0)
Current fixed speed machine
(RCUP-W2) 100% 100% 100% 100% 100% 50% 50%
New model
(RCUNP-WV1) 31% 21% 32% 29% 15% 14
Demand function as standard equipment
Up to 5 functions can be selected from 7 functions: current demand / forced thermo OFF / maximum load limit / forced full load / 2 temperature switching / external set temperature / forced pump operation. Available for power saving measures.
Optional parts (connector kit: CCK-1) are required.
Equipped with double-tube condenser
The condenser is changed from a plate type to a double-tube type. Redundancy with respect to water quality has been improved.
Expanded operating temperature range
Enables use in a wide range of temperatures so as not to be affected by the usage environment or cooling water temperature.
More smiles to life for one and all.
A more comfortable tomorrow for people and society.
With innovations that deliver happiness to the world,
we open new doors to the future.
Leading the field in home appliances and air conditioners for the digital age, and delivering solutions to support and enrich the lives of people around the world: Hitachi GLS is a lifestyle solution company that seeks to listen carefully to customers and resolve their lifestyle issues.
Hitachi Global Life Solutions, Inc. (“Hitachi GLS”) was created on April 1, 2019, through the merger of Hitachi Consumer Marketing, Inc. and Hitachi Appliances, Inc., with the aim of delivering valuable products and services to customers, through the integration of value chain processes, from product planning to design, manufacturing, sales and after-sales services.
Working under the slogan of “360-degrees of happiness: a happy life for each and every customer,” we seek to gain a closer understanding of customer lifestyles. By delivering well-designed functional products and sophisticated solutions to resolve individual customer lifestyle issues, through the utilization of the Hitachi Group’s value chain and digital technologies, we aspire to be a company that contributes to increasing the quality of life for customers around the world
Vendor Information
- Store Name: Hitachi Global Life Solutions, Inc.
- Vendor: Hitachi Global Life Solutions, Inc.
-
Address:
105-8410
Tokyo Minato-ku Nishi Shimbashi 2-chome
-
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage Machinery

Air-cooled chiller Matrix Advance (large capacity type) – Hitachi Global Life Solutions Inc.
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage MachineryAir-cooled chiller Matrix Advance (large capacity type) – Hitachi Global Life Solutions Inc.
Air-cooled cold screw chiller unit with improved energy efficiency and control functions
Significant reduction in annual power consumption.
(In the case of a 100 horsepower equivalent, approximately 19/22% reduction (50/60 Hz) compared to conventional models.
SKU: n/a -
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage Machinery

Air-cooled Chiller Matrix Sigma (Medium capacity type) – Hitachi Global Life Solutions Inc.
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage MachineryAir-cooled Chiller Matrix Sigma (Medium capacity type) – Hitachi Global Life Solutions Inc.
Matrix sigma (medium capacity type) with excellent installation and energy efficiency
New refrigerant R32 is adopted in consideration of environmental impact.
The addition of a medium-capacity type improves the flexibility of installation in small and narrow spaces.
All models achieve high rated COP.
The number of units can be controlled as a standard feature, enabling configuration of cooling capacities up to 800 kW.750-1000 type
RHGP AV(P)
RCGP AV (P)SKU: n/a -
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage Machinery

Air-cooled Chiller Matrix Advance – Hitachi Global Life Solutions Inc.
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage MachineryAir-cooled Chiller Matrix Advance – Hitachi Global Life Solutions Inc.
Air-cooled cold screw chiller unit with improved energy efficiency and control functions
Significant reduction in annual energy consumption.
Equivalent to 50 horsepower
Approx. 19/22% reduction (50/60Hz) compared to conventional models
1180-1800 type
RCF AZ(P)1SKU: n/a -
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage Machinery

Air-cooled Chiller Matrix Sigma (standard installation and renewal installation type) – Hitachi Global Life Solutions Inc.
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage MachineryAir-cooled Chiller Matrix Sigma (standard installation and renewal installation type) – Hitachi Global Life Solutions Inc.
New R32 refrigerant models with improved energy efficiency and environmental impact are now available for renewal installation.
1180 to 2000 type
RHGP AV (P)
RCGP AV (P)
rhnp av (p)2
RCNP AV (P)2
RHGP AV (P)X
RCGP AV (P)XSKU: n/a -
Cooling Refrigeration Equipment, Food & Beverage Machinery, Water Chillers

Water-cooled chiller Matrix Advance – Hitachi Global Life Solutions Inc.
Cooling Refrigeration Equipment, Food & Beverage Machinery, Water ChillersWater-cooled chiller Matrix Advance – Hitachi Global Life Solutions Inc.
Stable supply water temperature and reduced running costs. Reduction of initial cost including harmonic countermeasures.
Pursuing energy efficiency and serviceability Water-cooled screw chiller unit
In consideration of environmental impact, we have added a lineup of models that use the new refrigerant R1234yf, Models with new refrigerant R1234yf are available in the lineupSKU: n/a -
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage Machinery

Air-cooled cooling system (standard and inverter) – Hitachi Global Life Solutions Inc.
Air Cooled Chiller, Cooling Refrigeration Equipment, Food & Beverage MachineryAir-cooled cooling system (standard and inverter) – Hitachi Global Life Solutions Inc.
Improved rated cooling COP for all models.
High energy-saving performance is realized through improved performance at low load operation.
In addition, module control function is standard.SKU: n/a