Precision chillers PCU-R series – Apiste Corporation


Stability and precision at the highest level of the class

Compatible with a wide range of applications in regulating the temperature of the circulating water.

Report Abuse

High Precision and High Stability

Newly developed freezing cycle ”Triple valve control” and control algorithm “Parallel task control”

Equipped with Apiste’s unique refrigerating cycle “Triple valve control” containing three electronic control valves. Always monitors refrigerant temperature, pressure, and circulating temperature. Newly developed algorithm “Parallel task control”, based on information measured by various sensors, performs PID control of independent three electronic control valves and compact control heater in parallel and in high precision. Apiste’s unique refrigerating technology, which varies cooling capacity in a wide range from 0 to 100% without stopping the compressor, has realized “ultra high precision” “high stability” “wide temperature control range” and ”energy saving” which used to be difficult by conventional inverter control and hot gas control.

Three types of control mode

Operation pattern is selectable from three types of control mode in match with installation environment and versatile applications. Efficient and optimum performance can be fully demonstrated conforming to purpose of application. High-precision mode infinitely good in precision, eco mode in pursuit of energy efficiency, and normal mode with high stability are available.

[ Normal mode ]

Control mode putting emphasis on responsiveness and stability. When control shifts either to cooling side or heating side, stability can be maintained by its following capability.

[ Eco and high-response mode ]

Control mode putting emphasis on energy saving and responsiveness.
In cooling, operation at low power consumption is enabled without using a heater.
This mode is also effective when load fluctuation and disturbance are great.

[ High-precision mode ]

“Control mode effective when control of higher precision is required.
The true value is demonstrated in any temperature range from -10°C to 80°C.”

Wide range from -10 ℃ to 80 ℃

Temperature control range by Apiste’s parallel task control is a wide range from -10°C to 80°C. Continuous operation is enabled in all ranges without stopping the compressor. There is no instability by ON/OFF control, and high stability and high precision are always realized in any temperature range.

Resistant to high temperature circulating water return and load fluctuation

If the circulating water returning to the chiller unit becomes hot due to the load fluctuation of the equipment, the compressor may be turned off and the cooling function may not work in a general chiller. Apiste’s parallel task control can control a sudden rise in circulating water without stopping the compressor.

Energy saving and heater capacity -90%

Heater capacity was reduced by 90% in comparison with conventional freezing cycle 100% + heater control, and realized the energy saving. 15. Wide range from -10°C to 80°C

New structural design that pursues high reliability

Bottom tank structure

All the parts along circulating water route are installed at the top of tank, which is a structural design unique to Apiste. We adhered to the development of the top installation which is ready for accidental leakage. Newly developed high performance pump pumps up circulating water in the tank to the top, and feeds reliably up to the equipment.

Complete water leakage prevention structure, double safety pan

If any trouble should occur, leakage of circulating water is prevented from PCU unit to outside. Thorough measure against leakage is enabled by installing a primary safety pan at the top of the tank, and making the bottom of chiller unit the secondary safety pan. It realizes a high reliability on the field.

Double tank structure for energy saving and stability

The tank in chiller unit has a double-tank structure consisting of buffer tank and compact tank for control. Circulating water contained in buffer tank is pumped up and cooled by the cooler. Then it is sent to the compact tank for heating control. Heating control does not involve all circulating water in the tank, but only circulating water in the compact tank, which enables drastic energy saving. In addition, instability by irregular heating is eliminated, and high precision and stability are realized.

Cavitation preventing function

The phenomenon called “Cavitation” may occur in the maintenance of chiller unit. Even though circulating water is drained from the chiller unit, circulating water remains in the heat exchanger, heater tank, and equipment on load side, and bubbles remain in the circulating route when circulating water is fed again, and pressure from the pump is not transmitted. It is naturally impossible to send circulating water. All models of PCU Series are equipped with heater tank drain port for draining this residual water. It is a safety function when feeding water again after drained circulating water.

One-way exhaust structure (air cooling type)

The air-cooling type is designed so that the intake / exhaust paths for heat exchange are in the front and back of the main unit. Unlike the case where the intake and exhaust ports are on the side of the main unit, it is also possible to arrange multiple units closely. This saves space.

Abundant external input / output functions

“Equipped with various external input / output functions as standard to support various external devices and equipment.
It can be used for all purposes without adding new functions.”

1. Error output

Equipped with non-voltage contact output with maximum load current of AC250V 2A. It can be output to the outside when an alarm occurs. Not only can you communicate with the PLC, but you can also control patrol lamps and buzzers.

2. Various circulated water alarm output

I would like to pay close attention to the temperature control of circulating water. In the PCU series, warning values and caution values can be set in addition to the temperature upper and lower limit settings. Detects the temperature change of circulating water and reliably outputs it to the outside. Realizes complete temperature control of circulated water.

3.Operation stop output

Check the operation / stop of the chiller. It can be used as a confirmation signal when controlling the operation of the chiller from the outside, and it can also be notified by a lamp of the operating status of the chiller.

4. Automatic water supply valve output

Equipped with an output for a water supply valve that can automatically supply water to the chiller body. It is possible to save the trouble of supplying circulating water. The three-stage float sensor installed in the chiller unit tank detects full water, water supply, and water shortage, and outputs to the external water supply valve when water is supplied. The water supply valve can be turned ON / OFF, and automatic water supply is possible easily.

5.External temperature control

Equipped with an external temperature control input terminal as standard. Normally, the circulating water temperature is measured at the circulating water outlet in the chiller body, but the temperature can be controlled by an external sensor by switching. It supports primary PID control by the circulating water temperature of the work and cascade control by the temperature of the related parts of the work.

Primary PID control

The chiller unit is controlled to keep the temperature of circulating water near the work constant. The temperature of the circulating water is controlled directly to provide a stable control system, but the response to the disturbance is slow and the corrective action is limited.

Cascade control

In cascade control, the temperature of the object (PVm) is compared with the set temperature of the object (SVm), and the set temperature of the circulating water (SVs) is determined. Therefore, the temperature fluctuation due to disturbance is controlled quickly.

6. Emergency stop / alarm reset input

Equipped with an emergency stop input just in case. The chiller can be forcibly stopped by an external signal. It is possible to link the water leak sensor installed separately and the emergency stop button installed on the controlled device. E-99 is displayed at the time of emergency stop input and can be confirmed as a history. It can also be used by switching to the alarm reset input if necessary.

Emergency stop input from external devices such as leak detection sensor, emergency stop button, etc.

Emergency stop input can be switched to alarm reset input

7.External operation / stop input

Equipped with an external control input terminal that can be used to start and stop the PCU body from an external device. Since it has a dedicated circuit, it can be operated from the outside simply by preparing the contact signal. When used in combination with the operation / stop output, a higher and more reliable external control can be realized.

Supports data communication with PLC

Equipped with RS-232C as standard equipment for remote control and error code identification from equipment, and operation data collection with dedicated software to support various analyses.

External remote control / error code identification

Change the control settings and output settings from the device side. The settings can be changed according to the situation at the site, enabling optimal control. It is also possible to identify up to 31 error codes that the PCU unit has.

Data transmission

Various setting values input to the dedicated software PCU-S100 can be saved as a file, and the setting data can be collectively sent from the PC to the PCU.
It eliminates the need for input to the front panel of the chiller unit body. This is convenient when you need to input data to multiple chiller units or when you want to send the setting data to a chiller unit installed overseas.

Data collection

It is possible to collect data on various operating conditions and circulating water temperature of the chiller unit using the external software PCU-S100 and transfer it directly to Excel. It is useful for analyzing the correlation between the device to be temperature controlled and the chiller unit circulating water temperature.

[ Communication items list ]

Control settingsTimer/output settingInitial settingCommunication settingsCascade control setting
NameNameNameNameName
Control setting modeAlarm settingsDigital filtercommunication speedControl type
Control mode settingWater temperature upper limit alarmNumber of display digitsData lengthCascade scaling upper limit setting
AT startup screenWater temperature warning alarmKey lock settingKey lock settingCascade scaling lower limit setting
Proportional band (P)Water temperature lower limit alarmStandby mode
Yes / No
Stop bit lengthSecondary side auto tuning setting
Integration time (I)Water temperature caution alarmPassword settingBCC check functionSecondary side P value setting
Derivative time (D)Water temperature lower limit alarmOperation signal enable / disableCommunication addressSecondary side I value setting
Control water temperature (set value)Delay timeExternal temperature inputResponse delay timeSecondary D value setting
Water valve /
Operation output setting
Anti-freezing operationSecondary side digital filter setting
ON timerMain expansion valve
Initialization interval
Secondary side bias correction
OFF timerSecondary gain correction

[ List of communication items ]

Driving modeError historyCustom settingsCommunication only
The parameter
NameNameNameNameNameName
Error displayCompressor high pressureHeating expansion valveError history this timeEmergency stop / alarm
Reset input setting
PV value input
Control water temperature
(During measurement)
Compressor high pressureHigh pressure switchError history 1Circulating water flow rate
Alarm settings
Alarm reset
Outside temperaturePump operating timeCompressor protection
thermostat
Second error 2Bias correctionRun / stop
Control water pressureCompressor discharge temperatureFor full water
Float switch
Error history 3Gain correctionOperation status check
Cooling water temperatureCompressor suction temperatureFor water supply
Float switch
Auto /
Manual setting
Main valve
Initialize
For heating PID outputHeater overheat prevention temperatureFor water shortage
Float switch
PV value communication
Timeout setting
Cooling PID outputMain expansion valveEmergency stop inputFixed heater value setting
Heater current valueCooling expansion valve

Apiste was born with the philosophy of “”providing the best technology, products, and sincerity.

Development and sales of environmental improvement equipment, cooling equipment, and temperature control equipment

Environmental equipment
・High-Performance Dust Collector
・High-performance Mist Collector

Temperature control equipment Precision
・Chiller
・Oil chillers

Heat control equipment
・Control Panel Cooling unit
・Control panel heat exchangers
・Peltier cooling unit

Precision air conditioning equipment
・Precision air conditioners

Address
530 – 0004
1-4-16 Dojimahama, Kita-ku, Osaka, Japan (Aqua Dojima)

Nationwide Deployment of Sales and Technical Staff

Our company has established a one territory-one person system, placing dedicated sales and technical staff in every region across the country. This allows us to respond speedily to urgent matters, provide estimates and delivery inquiries, and send materials, effectively meeting all our customers’ needs.

Technical Support

Since our founding, we have accumulated a wealth of information and know-how by observing our products in use in various fields. This forms the basis of our comprehensive technical support system. We encourage you to feel free to consult us about any question, no matter how minor it may seem.

Strict Inventory Management for Quick Delivery

We have a system in place to quickly deliver the necessary products, underpinned by our meticulous inventory management. If you are facing issues with delivery times, please do not hesitate to contact us.

Ensuring Long-Term, Reliable Use of Our Products

Our company, grounded in field-oriented principles, focuses on designing products that are easy to maintain and service. We carry out inspections and provide inspection reports for the products you install. We believe that after-sales service adds significant value, especially for products used in demanding environments.

From Consultations and Various Documents to Convenient Selection Tools

At Apiste’s website, we concentrate on providing content that is useful for our customers. This includes inquiries, downloads of CAD data and catalogs, and online support for model selection.

Need more info ?

Chiller PCU series Catalog

Apiste Corporation

View Catalog

Supplier Information

  • Store Name: Apiste Corporation
  • Vendor: Apiste Corporation
  • Address: 530-0004
    Osaka Kita-ku 1-4-16 Dojimahama

High Precision and High Stability

Newly developed freezing cycle ”Triple valve control” and control algorithm “Parallel task control”

Equipped with Apiste’s unique refrigerating cycle “Triple valve control” containing three electronic control valves. Always monitors refrigerant temperature, pressure, and circulating temperature. Newly developed algorithm “Parallel task control”, based on information measured by various sensors, performs PID control of independent three electronic control valves and compact control heater in parallel and in high precision. Apiste’s unique refrigerating technology, which varies cooling capacity in a wide range from 0 to 100% without stopping the compressor, has realized “ultra high precision” “high stability” “wide temperature control range” and ”energy saving” which used to be difficult by conventional inverter control and hot gas control.

Three types of control mode

Operation pattern is selectable from three types of control mode in match with installation environment and versatile applications. Efficient and optimum performance can be fully demonstrated conforming to purpose of application. High-precision mode infinitely good in precision, eco mode in pursuit of energy efficiency, and normal mode with high stability are available.

[ Normal mode ]

Control mode putting emphasis on responsiveness and stability. When control shifts either to cooling side or heating side, stability can be maintained by its following capability.

[ Eco and high-response mode ]

Control mode putting emphasis on energy saving and responsiveness.
In cooling, operation at low power consumption is enabled without using a heater.
This mode is also effective when load fluctuation and disturbance are great.

[ High-precision mode ]

“Control mode effective when control of higher precision is required.
The true value is demonstrated in any temperature range from -10°C to 80°C.”

Wide range from -10 ℃ to 80 ℃

Temperature control range by Apiste’s parallel task control is a wide range from -10°C to 80°C. Continuous operation is enabled in all ranges without stopping the compressor. There is no instability by ON/OFF control, and high stability and high precision are always realized in any temperature range.

Resistant to high temperature circulating water return and load fluctuation

If the circulating water returning to the chiller unit becomes hot due to the load fluctuation of the equipment, the compressor may be turned off and the cooling function may not work in a general chiller. Apiste’s parallel task control can control a sudden rise in circulating water without stopping the compressor.

Energy saving and heater capacity -90%

Heater capacity was reduced by 90% in comparison with conventional freezing cycle 100% + heater control, and realized the energy saving. 15. Wide range from -10°C to 80°C

New structural design that pursues high reliability

Bottom tank structure

All the parts along circulating water route are installed at the top of tank, which is a structural design unique to Apiste. We adhered to the development of the top installation which is ready for accidental leakage. Newly developed high performance pump pumps up circulating water in the tank to the top, and feeds reliably up to the equipment.

Complete water leakage prevention structure, double safety pan

If any trouble should occur, leakage of circulating water is prevented from PCU unit to outside. Thorough measure against leakage is enabled by installing a primary safety pan at the top of the tank, and making the bottom of chiller unit the secondary safety pan. It realizes a high reliability on the field.

Double tank structure for energy saving and stability

The tank in chiller unit has a double-tank structure consisting of buffer tank and compact tank for control. Circulating water contained in buffer tank is pumped up and cooled by the cooler. Then it is sent to the compact tank for heating control. Heating control does not involve all circulating water in the tank, but only circulating water in the compact tank, which enables drastic energy saving. In addition, instability by irregular heating is eliminated, and high precision and stability are realized.

Cavitation preventing function

The phenomenon called “Cavitation” may occur in the maintenance of chiller unit. Even though circulating water is drained from the chiller unit, circulating water remains in the heat exchanger, heater tank, and equipment on load side, and bubbles remain in the circulating route when circulating water is fed again, and pressure from the pump is not transmitted. It is naturally impossible to send circulating water. All models of PCU Series are equipped with heater tank drain port for draining this residual water. It is a safety function when feeding water again after drained circulating water.

One-way exhaust structure (air cooling type)

The air-cooling type is designed so that the intake / exhaust paths for heat exchange are in the front and back of the main unit. Unlike the case where the intake and exhaust ports are on the side of the main unit, it is also possible to arrange multiple units closely. This saves space.

Abundant external input / output functions

“Equipped with various external input / output functions as standard to support various external devices and equipment.
It can be used for all purposes without adding new functions.”

1. Error output

Equipped with non-voltage contact output with maximum load current of AC250V 2A. It can be output to the outside when an alarm occurs. Not only can you communicate with the PLC, but you can also control patrol lamps and buzzers.

2. Various circulated water alarm output

I would like to pay close attention to the temperature control of circulating water. In the PCU series, warning values and caution values can be set in addition to the temperature upper and lower limit settings. Detects the temperature change of circulating water and reliably outputs it to the outside. Realizes complete temperature control of circulated water.

3.Operation stop output

Check the operation / stop of the chiller. It can be used as a confirmation signal when controlling the operation of the chiller from the outside, and it can also be notified by a lamp of the operating status of the chiller.

4. Automatic water supply valve output

Equipped with an output for a water supply valve that can automatically supply water to the chiller body. It is possible to save the trouble of supplying circulating water. The three-stage float sensor installed in the chiller unit tank detects full water, water supply, and water shortage, and outputs to the external water supply valve when water is supplied. The water supply valve can be turned ON / OFF, and automatic water supply is possible easily.

5.External temperature control

Equipped with an external temperature control input terminal as standard. Normally, the circulating water temperature is measured at the circulating water outlet in the chiller body, but the temperature can be controlled by an external sensor by switching. It supports primary PID control by the circulating water temperature of the work and cascade control by the temperature of the related parts of the work.

Primary PID control

The chiller unit is controlled to keep the temperature of circulating water near the work constant. The temperature of the circulating water is controlled directly to provide a stable control system, but the response to the disturbance is slow and the corrective action is limited.

Cascade control

In cascade control, the temperature of the object (PVm) is compared with the set temperature of the object (SVm), and the set temperature of the circulating water (SVs) is determined. Therefore, the temperature fluctuation due to disturbance is controlled quickly.

6. Emergency stop / alarm reset input

Equipped with an emergency stop input just in case. The chiller can be forcibly stopped by an external signal. It is possible to link the water leak sensor installed separately and the emergency stop button installed on the controlled device. E-99 is displayed at the time of emergency stop input and can be confirmed as a history. It can also be used by switching to the alarm reset input if necessary.

Emergency stop input from external devices such as leak detection sensor, emergency stop button, etc.

Emergency stop input can be switched to alarm reset input

7.External operation / stop input

Equipped with an external control input terminal that can be used to start and stop the PCU body from an external device. Since it has a dedicated circuit, it can be operated from the outside simply by preparing the contact signal. When used in combination with the operation / stop output, a higher and more reliable external control can be realized.

Supports data communication with PLC

Equipped with RS-232C as standard equipment for remote control and error code identification from equipment, and operation data collection with dedicated software to support various analyses.

External remote control / error code identification

Change the control settings and output settings from the device side. The settings can be changed according to the situation at the site, enabling optimal control. It is also possible to identify up to 31 error codes that the PCU unit has.

Data transmission

Various setting values input to the dedicated software PCU-S100 can be saved as a file, and the setting data can be collectively sent from the PC to the PCU.
It eliminates the need for input to the front panel of the chiller unit body. This is convenient when you need to input data to multiple chiller units or when you want to send the setting data to a chiller unit installed overseas.

Data collection

It is possible to collect data on various operating conditions and circulating water temperature of the chiller unit using the external software PCU-S100 and transfer it directly to Excel. It is useful for analyzing the correlation between the device to be temperature controlled and the chiller unit circulating water temperature.

[ Communication items list ]

Control settingsTimer/output settingInitial settingCommunication settingsCascade control setting
NameNameNameNameName
Control setting modeAlarm settingsDigital filtercommunication speedControl type
Control mode settingWater temperature upper limit alarmNumber of display digitsData lengthCascade scaling upper limit setting
AT startup screenWater temperature warning alarmKey lock settingKey lock settingCascade scaling lower limit setting
Proportional band (P)Water temperature lower limit alarmStandby mode
Yes / No
Stop bit lengthSecondary side auto tuning setting
Integration time (I)Water temperature caution alarmPassword settingBCC check functionSecondary side P value setting
Derivative time (D)Water temperature lower limit alarmOperation signal enable / disableCommunication addressSecondary side I value setting
Control water temperature (set value)Delay timeExternal temperature inputResponse delay timeSecondary D value setting
Water valve /
Operation output setting
Anti-freezing operationSecondary side digital filter setting
ON timerMain expansion valve
Initialization interval
Secondary side bias correction
OFF timerSecondary gain correction

[ List of communication items ]

Driving modeError historyCustom settingsCommunication only
The parameter
NameNameNameNameNameName
Error displayCompressor high pressureHeating expansion valveError history this timeEmergency stop / alarm
Reset input setting
PV value input
Control water temperature
(During measurement)
Compressor high pressureHigh pressure switchError history 1Circulating water flow rate
Alarm settings
Alarm reset
Outside temperaturePump operating timeCompressor protection
thermostat
Second error 2Bias correctionRun / stop
Control water pressureCompressor discharge temperatureFor full water
Float switch
Error history 3Gain correctionOperation status check
Cooling water temperatureCompressor suction temperatureFor water supply
Float switch
Auto /
Manual setting
Main valve
Initialize
For heating PID outputHeater overheat prevention temperatureFor water shortage
Float switch
PV value communication
Timeout setting
Cooling PID outputMain expansion valveEmergency stop inputFixed heater value setting
Heater current valueCooling expansion valve

Apiste was born with the philosophy of “”providing the best technology, products, and sincerity.

Development and sales of environmental improvement equipment, cooling equipment, and temperature control equipment

Environmental equipment
・High-Performance Dust Collector
・High-performance Mist Collector

Temperature control equipment Precision
・Chiller
・Oil chillers

Heat control equipment
・Control Panel Cooling unit
・Control panel heat exchangers
・Peltier cooling unit

Precision air conditioning equipment
・Precision air conditioners

Address
530 – 0004
1-4-16 Dojimahama, Kita-ku, Osaka, Japan (Aqua Dojima)

Nationwide Deployment of Sales and Technical Staff

Our company has established a one territory-one person system, placing dedicated sales and technical staff in every region across the country. This allows us to respond speedily to urgent matters, provide estimates and delivery inquiries, and send materials, effectively meeting all our customers’ needs.

Technical Support

Since our founding, we have accumulated a wealth of information and know-how by observing our products in use in various fields. This forms the basis of our comprehensive technical support system. We encourage you to feel free to consult us about any question, no matter how minor it may seem.

Strict Inventory Management for Quick Delivery

We have a system in place to quickly deliver the necessary products, underpinned by our meticulous inventory management. If you are facing issues with delivery times, please do not hesitate to contact us.

Ensuring Long-Term, Reliable Use of Our Products

Our company, grounded in field-oriented principles, focuses on designing products that are easy to maintain and service. We carry out inspections and provide inspection reports for the products you install. We believe that after-sales service adds significant value, especially for products used in demanding environments.

From Consultations and Various Documents to Convenient Selection Tools

At Apiste’s website, we concentrate on providing content that is useful for our customers. This includes inquiries, downloads of CAD data and catalogs, and online support for model selection.

Need more info ?

Chiller PCU series Catalog

Apiste Corporation

View Catalog

Supplier Information

  • Store Name: Apiste Corporation
  • Vendor: Apiste Corporation
  • Address: 530-0004
    Osaka Kita-ku 1-4-16 Dojimahama