HICLAVE HV-Ⅱ series – HIRAYAMA Manufacturing Corporation
Sterilization as expected. Color touch panel
Color touch panel
Electro-mechanical lid lock system
Memory function
Dual interlock mechanism
Lid lock release temperature setting
Air removal time setting
Forced cooling unit(option)
Features & Functions
Color touch panel
A color touch panel allows an operator to understand the operation screen contents at a glance.
Electro-mechanical lid lock system
The lid can be opened and closed easily and reliably with the one-touch lever. A pressure seal method is used as a safety measure.
Dual interlock mechanism
The lid is locked by dually detecting the chamber pressure and chamber temperature during operation. The lock state is maintained even if an operation is manually interrupted.
Memory function
Up to 8 patterns for each mode can be registered according to the purpose of use.
The lid lock release temperature setting
The lid lock release temperature can be set up for each mode or program to secure safety at the time of unloading.
Air removal time setting
It is effective for sterilization of Durham tubes etc. from which air is difficult to escape.
Dual detection system for residual air
The residual air which may cause sterilization failure is dually detected to always maintain the appropriate sterilization conditions for loads.
※Detection of residual air is performed dually when the chamber pressure is normal (during air removal by gravity displacement) and when the chamber is pressurized (during air removal by pressure exhaust).
Forced cooling unit (option)
After sterilization, the chamber pressure is lowered by cooling with a forced cooling unit (air-cool) to shorten the time to unloading.
Programmable auto-start function
It is a timer function that starts an operation at the set time.
※The operation start time can be set up to 1 week later.
Easy to use with color touch panel
A color touch panel allows an operator to understand the operation screen contents at a glance.

Confirmation items are notified at startup.

When the power is turned on, the confirmation items before use are displayed. You can reduce the trouble by implementing the confirmation items.
A mode can be selected simply by touching the screen.

A mode can be selected with the simple operation of tou-ching the desired mode from 5 modes displayed on the color touch panel and pressing the start button.
Color display makes it easier to understand various settings.
The settings of temperature, time, warming and exhaust can be easily changed by touch operation while checking the color screen.The set contents can be registered up to 8 patterns. It is very convenient when sharing and using with a plurality of names.

Sterilization temperature setting

Registration and selection of memory
Security & Safety
Various information such as settings, safety and warnings are displayed on a color screen.
More detailed contents are shown by text information.

[ Alarms ]
11 kinds of alarms such as a low water heating alarm are displayed.

[ Alarm history ]
Alarm occurrence date, alarm contents and stage ID number are displayed.

[ System information ]
Progrm version number, cycle count, next self inspection date are displayed.
Operation cycle of each mode (Up to 8 patterns for each mode can be registered.)

Options for upgrading a system (retrofittable)
| Forced cooling unit (air-cool) |
Floating sensor | Recorder | Core temperature sensor | |
|---|---|---|---|---|
![]() |
![]() |
![]() |
||
| Used to shorten the time to unloading after sterilization | A sterilization timer operates after the temperature of the materials to be sterilzed reaches the set temperature. | (Image is a chart type recorder.) ・Chart type recorder: 6-point dotting ・Hybrid recorder: 8-point dotting ※Chart width: 100 mm ※Class 2 T-type thermocouple included |
Class 2 T-type thermocouple Connection with recorder is required. | |
| Printer | Automatic water supply unit |
|---|---|
![]() |
![]() |
| Thermal print type | Manual water supply to the chamber becomes unnecessary. |
Options
| Round wire mesh basket, stainless steel | Sterilization bucket, stainless steel | Round wire mesh basket with solid bottom, stainless steel |
|---|---|---|
![]() |
![]() |
![]() |
| [For HV-25Ⅱ] φ210 x H255 mm[For HV-50Ⅱ] φ270 x H220 mm φ270 x H270 mm[For HV-85Ⅱ] φ380 x H285 mm[For HV-110Ⅱ] φ380 x H375 mm |
[For HV-25Ⅱ] φ210 x H255 mm[For HV-50Ⅱ] φ270 x H220 mm φ270 x H270 mm[For HV-85Ⅱ・with holes / without holes] φ390 x H285 mm[For HV-110Ⅱ・with holes / without holes] φ390 x H375 mm |
It is recommended to use it when using a sterilization bag. A large capacity and bucket-shape bottom can prevent the chamber from being contaminated when a sterilization bag is broken.
[For HV-25Ⅱ] [For HV-50Ⅱ] |
| Detergent for autoclave | Sterilization bag | Deodorizer |
|---|---|---|
![]() |
![]() |
![]() |
| Detergent to remove culture media, water scale sticked to the inside of a chamber
[Standard amount of use] ※Take out the materials at the time of use. 500 ml |
Special structure reinforced film. Heat resistant temperature is 130℃[Type:A] 200 pcs 500 x 700 mm [Type:B] 200 pcs 620 x 820 mm※Use it without closing the mouth. |
Deodorizer for the “unpleasant odor” generated during sterilization of culture media etc.
It melts smoothly in the sterilization process and exerts a deodorization effect. Standard amount of deodorant according to the autoclave capacity |
| Sterilization tape, Sterilization label, Sterilization bag |
|---|
![]() |
| ■Sterilization tape: Clear color change makes it easy to identify exposure to sterilization process. ■Sterilization label: Paste directly on the object to be sterilized, you can check the sterilization treatment. After sterilization, the letters “sterilized” appear and it can be easily distinguished from untreated materials. ■Sterilization bag: There are sterilization bags that are made of paper, roll type or one seal back type. Most of them are heat seal type, but tape seal type and aluminum plate seal type can be also available.※Ask us for prices and more details. |
“STERILIZING SIMPLY AND WELL”
Since its foundation in 1924, we have continued to pursue the fields of medical and scientific equipment for 90 years, with various sterilizations, incubators, and highly accelerated stress test chambers as our main products.

Vendor Information
- Store Name: HIRAYAMA Manufacturing Corporation
- Vendor: HIRAYAMA Manufacturing Corporation
-
Address:
345-0845
Saitama Kasukabe-shi 2-6-5 Toyono-cho
-
Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer

HICLAVE HVA series – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHICLAVE HVA series – HIRAYAMA Manufacturing Corporation
Large capacity, Economical and excellent cost performance.Forced cooling unit as standard
Electro-mechanical lid lock system
Dual interlock mechanism
Forced cooling unitSKU: n/a -
Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer

High Pressure Steam Sterilizer HVE-50 – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHigh Pressure Steam Sterilizer HVE-50 – HIRAYAMA Manufacturing Corporation
Easy operation. More safety and more user-friendly features !
User-Friendly Features and Improved Basic Performance User-Friendly Features and Improved Basic Performance
1. Electromechanical lock system.
2. Dual-sensing interlock mechanism.
3. Pulse exhaust system (HVE-50).
4. Memory function (program your own).
1. Electromechanical lock system.
2. Dual-sensing interlock mechanism.
3. Pulse exhaust system (HVE-50).
4. Memory function (program your own).
5. Space – saving design.
6. Process status display.
7. Forced cooling fan as
standard equipment (HVA-85/110)
and provided as option (HVE-50).SKU: n/a -
Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer

HICLAVE HVP series – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerHICLAVE HVP series – HIRAYAMA Manufacturing Corporation
This autoclave is made by incorporating a high performance vacuum pump into the HV series autoclave and equipped with fully automatic drying function.
Clean drying without contamination
Pre-vacuum air removal using a vacuum pump
Electro-mechanical lid lock system
Dual interlock mechanismSKU: n/a -
Hast Chamber, Testing Equipment, Testing Instrument & Equipment

PC-R9D series – HIRAYAMA Manufacturing Corporation
Hast Chamber, Testing Equipment, Testing Instrument & EquipmentPC-R9D series – HIRAYAMA Manufacturing Corporation
PC-R9D series HAST Chambers
The PC-R9D series HAST chambers are equipped with the latest temperature humidity program controller, and have advanced interface functions such as a LCD touch panel and a function remotely controlled by an external terminal.
SKU: n/a -
Chemical & Pharmaceutical Machinery, Industrial Machinery, Sterilizer

Full-automatic Autoclave with Drying Function HRH – HIRAYAMA Manufacturing Corporation
Chemical & Pharmaceutical Machinery, Industrial Machinery, SterilizerFull-automatic Autoclave with Drying Function HRH – HIRAYAMA Manufacturing Corporation
Horizontal Autoclave with One-touch Lid Interlock System
Clean drying without contamination
Pre-vacuum air removal using a vacuum pump
Electro-mechanical lid lock system
Dual interlock mechanism
Dual detection system for residual airSKU: n/a -
Hast Chamber, Testing Equipment, Testing Instrument & Equipment

Highly Accelerated Stress Test Chamber PC-702R8 – HIRAYAMA Manufacturing Corporation
Hast Chamber, Testing Equipment, Testing Instrument & EquipmentHighly Accelerated Stress Test Chamber PC-702R8 – HIRAYAMA Manufacturing Corporation
A dual vessel structured HAST chamber with color touch panel has many superiorities.
There are two types of operation modes.
A fixed-value operation mode, and a programmed operation mode that allows registration of total 1500 steps within maximum 150 operation patterns are equipped.SKU: n/a